Steps to Use:
With the Accessport installed navigate to the "gauges" menu.
If it's the first time you've gone to the gauge menu of the Accessport it will prompt you to ask how many monitors you want to display. The selection can be updated later in the Gauge Setup menu.
From the main gauge display, you can simply hit the center button on the Accessport in order to start logging. (if logging manually, if autologging is enabled it will automatically start at this point). If you haven't pre-selected anything there are default parameters that will be logged which are typically the ones COBB Customer Support will ask you for. Note that the Accessport will show Logging at the top of the screen and at the bottom will let you know the logging rate.
In order to stop logging, you'll need to hit the center button on the Accessport again. Notice it now tells you it’s not logging.
Available Adjustments and How to Make Them:
Activating Autologging
From the main menu of the Accessport select Gauges
Navigate up to the Setup option, then Configure Datalogging. This will bring up the list of selectable datalogging parameters.
It’ll pull up the list of datalogging parameters. Scroll up once again to the setup menu for this page, and go to Configure Logging Mode
From here you can adjust between two modes.
Manual Mode - You’ll need to press the center Accessport button when on the main gauges screen in order to start logging. Then press it again to stop.
Automatic - Whenever the Accessport is on the gauges screen it will start to log. As the Accessport runs out of space to datalog it will begin to delete older logs to avoid filling up the system.
Once selected you should see different messages on the main gauges screen depending on if you are in automatic or manual mode, and currently logging or not currently logging. At any time you can stop an automatic log by pressing the center button.
How to change Datalogging Monitors
- Link your Accessport to your vehicle and turn it on.
- Select Gauges from the main menu
- Go up and select Settings, then go to Configure Datalogging
- You'll now see a list of monitors to select or deselect at will. If you exceed what the ECU is capable of logging at a reasonable rate, the AP will give you a warning message to remove parameters. Some parameters may take more memory to log than others.
- On the monitor select screen you can also scroll up to Setup for a few options.
- Select Clear monitors to clear all
- Reset to Defaults to go back to the default
- Save a Datalog Preset Saves your current logged items so you can load it again later.
- Load a Datalog Preset lets you load a custom log list you saved, or were sent by a tuner/COBB and loaded onto the AP through Accessport Manager
- When finished simply hit the back button to return to the gauges
Related Articles
How to Change Datalog Monitors - explains how to go through the process in order to change datalog monitors.
How to transfer maps and datalogs using Accessport Manager - covers migrating maps and datalogs to your computer
How to Change/Reset Displayed Gauges - explains the process for changing the displayed gauges.
Accessport V2
Steps to Use:
Related Articles:
Contact Us:
COBB Customer Support
Web Support and Tech Articles: COBB Tuning Customer Support Center
Email: support@cobbtuning.com
Phone support available 9am to 6pm Monday-Thursday. 9am to 4pm Friday (CST)
866.922.3059
return to www.cobbtuning.com