Tech Bulletin - COBB / Injector Dynamics "1300cc" Injectors
By: Mike McGinnis
Requires Different Injector Data
1300 Injectors
ID1300 or 1300cc - Uses ID1300 or ID1300x calibration data - discontinued
ID1300x or 1300x - Uses ID1300 or ID1300x calibration data, no known change in product - discontinued
ID1300x2 or 1300x2- Redesigned product, uses ID1300x2 or ID1300-XDS calibration data which includes large differences in small IPW compensation, as well as other changes. Phasing out as XDS phases in.
ID1300-XDS or 1300-XDS - Uses ID1300x2 or ID1300-XDS calibration data. These injectors feature high and low slope matching for improved low slope behavior, but still use the same calibration data as ID1300x2.
Can Use Existing Data
1050 Injectors
- ID1050x or 1050x- Uses ID1050x or ID1050-XDS calibration data. Phasing out as XDS phases in.
- ID1050-XDS or 1050-XDS - Uses ID1050x or ID1050-XDS calibration data. These injectors feature high and low slope matching for improved low slope behavior, but still use the same calibration data as ID1050x