  • Ethanol Sensor Voltage has been added to help troubleshoot errors that may come up when you are receiving a dtc for the ethanol sensor at a fixed voltage

  • TGV monitors reduced. Because custom sensors are only supported on TGV Right, the monitors have been limited to.

    • Sensor Input Monitor Only TGV Right

    • Sensor Input Voltage TGV Right

New DTCs

COBB06

DTC

Description

Cause

COBB1

Ethanol Sensor Voltage Low Input

Typically caused by a short or a break in the harness (or the content sensor being unplugged. Could also be caused by contaminants in fuel

COBB2

Ethanol Sensor Voltage High Input

High voltage can be caused by water in the fuel, or a short on the sensor. (water in the connector)

COBB6

COBB NexGen Flex Fuel module not detected

COBB07Module is likely unplugged.

COBB7

COBB NexGen module lost communication

Intermittant connection with the module or lost module communication entirely, typically due to a loose connection.

Info