How to Use COBB Transmission Brake and Bump Box
COBB Custom Features: Ford EcoBoost Mustang Transmission Brake and Bump Box
Tables and Descriptions
Load Target
We have created a custom transbrake-specific load targeting system to offer ultimate launching control without influencing power available while driving. When transbrake is engaged, and accelerator pedal position has exceeded the table value for 'Transbrake Load Target Pedal Threshold', load targets will be hijacked by the custom transbrake load
targets.
The default value and OTS calibration value for this pedal threshold is 40%. This means that while transbrake is engaged and APP is between 0% and 40%, load control will
While this load target hijack is active, you will see Airflow Limit Src. = 5 (LSPI) and Load Desired (TQ Control) will reflect the load limit from these tables. Notice that these tables have an axis of APP - this will allow you to modulate engine load when launching to adjust for variable traction conditions.
In addition to modulating engine load via APP, the Accessport has a load offset adjustment that will allow the user to increase or decrease load when launching. The minimum and maximum values for adjustment can be found in 'Transbrake Load Target User Adjust (Max)' and 'Transbrake Load Target User Adjust (Min)'. The functionality of the AP adjustment will be covered later in this guide.
Consider an example:
- The user is launching in 1st gear, so load targets will come from the table 'Transbrake Load Target (1st Gear)
- APP is 100%
With no load offset changes, Load Desired (TQ Control) will be 1.600%.
If the user adjusts the load offset to its maximum of +0.500%, Load Desired (TQ Control) will be (1.600+0.500) = 2.100%
If the user adjusts the load offset to its minimum of -0.500%, Load Desired (TQ Control) will be (1.600-0.500) = 1.100%
Safety Thresholds:
In order to avoid unneccessary- Default Value: 10 seconds.
- Default Value: 50 RPM
- Default Value: 2 knock counts.
Staging Control:
Staging control configuration can be split into two separate categories: Bump and Creep.
Bump control is pretty simple - you have a realtime table controlling the duration of the bump (Transbrake Bump Time), and a table that controls bump ramp out (Transbrake Bump Ramp Out Time). Bump ramp out an important factor for avoiding the sort of violent rocking back-and-forth that can happen on a conventional bump system.Staging Control
Creep mode has more complex control. The core of the system is the Transbrake Creep Slip Target. This is an RPM target for slip on the reverse clutch pack. When creep is activated, line pressure to the reverse clutch pack is decreased to permit slip. There is a base, feed-forward pressure table as well as P and I controls. The PI system will account for control over error between slip target and slip actual.
Tables and Descriptions
Transbrake Enable/Disable- Realtime
A real time table to activate or disable the transbrake system. All ROM's have it active by default, to change the state you'll need to be either live connected to the vehicle in Accesstuner Pro/ Accesstuner. Or utilize the Accessport's adjustments menu to disable it.Load Target
Staging Control